Cga 660 valve drawing download

These nitrous oxide bottle outlet gaskets are designed for the zex 660 cga to 4 an bottle adapter. Smith high purity cga 660 regulator two stage stainless steel. Dichlorodifluoromethane r12 0100 660 cg1, 2, 3, 7 dichlorofluoromethane r21 0100 660 n. Zex bottle valve washers ns6717 free shipping on orders. They may also be configured for use on returnable cylinders having pressures to 2400 psig.

View abstract product details document history cga v1 complete document. Examples of cga fittings would be cga 580 for nonflamable, nonoxidizing gasses such as nitrogen, argon, or helium. Cga590 sulfur hexafluoride formerly industrial air. This co2 valve is made from heavyduty forged brass and is specifically designed for use with aluminum carbon dioxide cylinders. Chart gas cga valve fitting data department of molecular. Cga590 to cga580 cylinder to regulator adaptor a892. Thoroughbred industrial cylinder exchange cga200 valve to. Sherwood valve cga 320 straight thread beverage gas supplies. Smith high purity cga 660 regulator two stage stainless. Chrome plated brass nut y99 cga c14 hand tight nut y99 cga htnc brass cga kits includes nipple, nut and washer if applicable chrome plated brass cga kit y99 cga ck chrome plated brass wcheck valve cga kit y99 cga ccvk stainless steel cga nipples stainless steel nipple y99 cga c43 stainless steel nipple with check valve y99 cga c43cv. All gv valves are 100% leak tested and utilize a plug style pressure relief device. Advanced specialty gas equipment 151 technical information cga connections continued cga 702 1.

These aluminumbodied, singlestage, pistonstyle regulators have eight flow settings from 0. Gasco cv2 control valve for 17 and 34 liter cylinders. The most commonly used gases the compressed gas association primary outlet to be used with each gas the sherwood valves designated for use with this gas. Compressed gas association cga v1 cylinder valve connections. The same chlorine valve can be used with a cga 660 connector nut connection or with a cga 820 yoke connection. Manufactured in the usa to meet a wide variety of compressed gas association outlet designations, including cga 320, cga 326, cga 346, cga 350, cga 540, cga 555, cga 580, cga 590, cga 660, and others. Parker hannifin corporation hydraulic valve division 520 ternes avenue elyria, ohio 44035 usa tel. Each gas and each different type of gas service has a unique connection assigned to it by the compressed gas association cga. Cylinder valve outlets and connections air liquide. The compressed gas association primary outlet to be used with each gas the sherwood valves designated for use with this gas the pressure relief device styles that are authorized by the dot for use with these gases please note.

Chch3 510, 660 halocarbon116 c2f6 660, 320 716 silane sih4 350 632 halocarbon41 ch3f 350 724 silicon tetrachloride sicl4 330 636. The sherwood cylinder valve selection charts are partial lists extracted from the cga v1 and s1. Also search for wide range of cylinder to regulator adaptors products with guarantee assured. Also search for wide range of cylinder to regulator adaptors products with. Cga 660 refrigerant gases 3000 psig chrome plated warning. Examples of cga fittings would be cga580 for nonflamable, nonoxidizing gasses such as nitrogen, argon, or helium. Cylinder valve connections applied home healthcare. Gas cga diss ammonia 660 720 argon 580718 arsine 350632 boron trichloride 660 634 boron trifluoride 330642 carbon dioxide 320716 carbon monoxide 350724 chlorine 660 728 deuterium 350724. America and cga compressed gas association outlet connection standards except for the ultrahigh integrity connections which are globally recognized. Whenever possible, valve outlets standardized by the compressed gas association and accepted by the american national standards institute are used. Get cga 590 to cga 580 cylinder to regulator adaptor from our online store at evergreen midwest. Chrome plated brass nut y99cgac14 hand tight nut y99cgahtnc brass cga kits includes nipple, nut and washer if applicable chrome plated brass cga kit y99cgack chrome plated brass wcheck valve cga kit y99cgaccvk stainless steel cga nipples stainless steel nipple y99cgac43 stainless steel nipple with check valve y99cgac43cv. Cga standards continued air liquide america specialty gases llc. Cga cylinder to regulator adaptersgentec corporation.

The 6000 series regulators are for use with 58 liter and 103 liter nonrefillable cylinders having a c10 5818 unf inlet connection. Brass cga nut chrome plated brass nut y99 cga c14 hand tight nut y99 cga htnc brass cga kits includes nipple, nut and washer if applicable chrome plated brass cga kit y99 cga ck chrome plated brass wcheck valve cga kit y99 cga ccvk stainless steel cga nipples stainless steel nipple y99 cga c43. Part number description prop 65 warning outlet material max pressure size type. Position indicators and combi switchboxes fieldbus systems control valves positioners and process controllers connection technology accessories.

Sherwood global oring style residual pressure valve 34 cga 580 with 3360 psi. These files are stored in several file formats commonly used in engineering cad programs. Phoenix controls has created a set of drawings pdf, 2d and 3d of standard valve products to be used by customers for their system design. Products on this website can expose you to chemicals including lead which is known to the state of california to cause cancer, birth defects or reproductive harm. Common applications include beverage dispensing and welding. Quicktest cga 580 cylinder valve adapters connect to any cga 580 cylinder valve without a wrench or thread sealant. Designation small end major diameter mm taper on diameter thread angle thread per inch tpi specification remarks 1a 1827 ngt 9. Designed for use with all yokes made to cga 860 drawing specifications. Just place the quick connector onto the cylinder valve until it stops.

You will find the step files in our customer portal and can use these for your planning projects. Save time and money by ensuring you have the correct adaptor for your acetylene tanks and regulators. Further information on the range and a gas reference chart can be seen below and also in the product data sheet that can be downloaded here. Cylinder valve selection quick reference for valve abbreviations. Bottle connectors for bs341, din477, cga standards. Get cga590 to cga580 cylinder to regulator adaptor from our online store at evergreen midwest. Cga660 refrigerant gases valve outlet operates at a pressure of 3000 psig. Scott supplies gases in cylinders with valves having bs, cga, din and nen.

Gas cgadiss ammonia 660720 argon 580718 arsine 350632 boron trichloride 660634 boron trifluoride 330642 carbon dioxide 320716 carbon monoxide 350724 chlorine 660728 deuterium 350724. Cga diss name chemical formula cga diss acetylene c2h2 510, 300 hydrogen chloride hcl 330 634 air 346, 590 hydrogen fluoride hf 660 638 ammonia nh3 240705, 660 720 hydrogen sulfide h2s 330 722 argon ar 580 718 hydrogen selenide h2se 330 632 arsine ash3 350 632 isobutane chch3. Customs services and international tracking provided. Dimensional drawing cga diss series 57 series outlet adaptors and blank plugs material a nickel 200 pctfe aluminum 50 series spectratite gaskets h 0. These regulators provide constant delivery pressure regardless of. Cga590 is used for compressed air and cga326 is used for nitrous oxide.

Cga 590 sulfur hexafluoride formerly industrial air. Clickmate tw157 for filling of breathing air scbas up to 6,000psi cga 346347 the clickmate tw157 provides a connection in seconds to the cga thread of the cylinder valve without hand wrench tightening. We would be pleased to provide you with 3d construction drawings for many of our products. These nitrous oxide bottle outlet gaskets are designed for the zex 660 cga to 4 an bottle adapter fittings. Halocarbon14 cf4 580, 320 716 phosphine ph3 350, 660 632 halocarbon22 chclf2 660 propane c3h8 510, 660 halocarbon23 chf3 660 716 propylene ch2. Whenever possible, valve outlets standardized by the compressed gas association are used. These regulators provide constant delivery pressure regardless of inlet pressure fluctuations. This product can expose you to chemicals including lead which is known to the state of california to cause cancer, birth defects or reproductive harm. Sherwood co2 gas service brass cylinder valve tapered.

Cga660 outlet adapter 14 ngorhext to 14 npt female. Components not rated gastight are intended only to keep valve outlets clean and. The drawings of valve outlets and connections shown on these introductory pages are those now in use by matheson trigas and in common use by the compressed gas industry. Our 2020 annual meeting at the royal sonesta new orleans in new orleans, louisiana, is. Cylinder valve inlet connections taper threads 34 cl iii ii iii w 19. The cga connection standard numbers are followed by a multipart, sequentially listed descriptive code. Compressed gas association cylinder valve fitting specifications apc2386194232 101602 1. Compressed gas association cga v1 cylinder valve connections following is a summary of the north american compressed gas association cga v1 cylinder valve outlet fittings. Refer to gases chart on page 8 to find a valve suited for your application. Compressed gas association cylinder valve fitting specifications. Cga and diss compressed gas cylinder valves and connections. Air products cylinder valve outlets and connections are designed and constructed to conform to the specifications established by the compressed gas association u.

All dimensions are in inches, are for reference only, and are subject to change. Regulator with cga 660 refillable cylinder multiflow regulator the 6000 series regulators are for use with 58 liter and 103 liter nonrefillable cylinders having a c10 5818 unf inlet. This connection system is designed to help reduce mixups involving compressed gases. Gasco cv2 control valve for 17 and 34 liter cylinders, cga 600. Sherwood oring style residual pressure global valve with 3360 psi cga580. Parker hannifin corporation hydraulic valve division 520 ternes avenue elyria, ohio. All dimensions are based on controlled phoenix controls part drawings.

Compressed gas cylinder valve outlet and inlet specifications. Compressed gas assocationcga number on valve tells you a lot cga plus 3 digits e. Learn more about washer ptfe 3000psi cga 660, washer replacement at. Cga660 refrigerant gases 3000 psig chrome plated warning. Cylinder valve selection quick reference for valve. Founded in 19, the compressed gas association is dedicated to the development and promotion of safety standards in the industrial, medical, and food gases industry. Complete document standard for compressed gas cylinder valve outlet and inlet connections. Hydraulic valve drawings truck wetline systems engineering your success. Medical oxygen cylinders are equipped with either cga870 or cga540 valves.

551 1445 436 768 229 1241 57 1167 1147 893 1251 1338 704 634 425 1251 358 174 625 789 1234 1457 647 401 465 1315 1417 1313 266 675 445 1046 1103 1479 830 867 539 824 646 856 177 1491 683 763 1192